PED and CE Marking

Classified, assessed and CE marked under the PED.

Contact us

Pressure equipment rules for the European market

Any pressure equipment installed in the European Union or the wider European Economic Area falls under the Pressure Equipment Directive, 2014/68/EU. It is a law, not a design code: it sets the essential safety requirements a vessel must meet and the conformity assessment route the maker must follow, and it is satisfied by designing to a harmonized standard such as EN 13445 or to another recognized code, ASME included, with a demonstration that the essential requirements are met. The result is a CE mark on the nameplate, which is what allows the unit to be installed.

For a sanitary exchanger the process has three steps: classify the unit into a PED category from its pressure, volume and fluid, follow the assessment module that category allows, and mark it. Small units on water may fall below the thresholds entirely; a larger unit on steam will need a notified body involved. Knowing the category early avoids a redesign when the unit is already built.

Category I

  • Self-assessed under module A
  • Technical file and declaration of conformity
  • CE mark, no notified body number
VS

Categories II-IV

  • Notified body takes part
  • Design examination plus witnessed testing
  • Four-digit notified body number beside CE

PED classification and assessment

Classification inputs

  • PS: Maximum allowable pressure in bar; each side classified
  • V: Volume in liters of the pressure chamber being classified
  • Fluid group: Group 1 hazardous (flammable, toxic); Group 2 all others, including water and steam
  • State: Gas or liquid at PS; steam and vapors count as gas
  • Chart: PS times V plotted on the annex II table for the fluid and state
  • Result: SEP, or category I, II, III or IV; the most severe chamber governs

Assessment and marking

  • SEP: Sound engineering practice; no CE mark, no declaration; maker's marking and instructions
  • Category I: Module A, internal production control; CE mark, no notified body
  • Category II: Module A2 or D1 or E1; notified body monitors or inspects
  • Category III: Modules B plus D, E, F or C2, or H; type or design examination
  • Category IV: Modules B plus D or F, G unit verification, or H1; full involvement
  • Nameplate: CE mark, notified body number where applicable, PS, TS, V, year

Classify first; the category decides the paperwork

Taking a sanitary exchanger through PED

Classifying the unit

Each pressure chamber of the exchanger is classified on its own: the shell side and the tube side, and on a plate unit each fluid circuit. For each, take the maximum allowable pressure PS in bar gauge, the chamber volume V in liters, and decide the fluid group and state. Sanitary duty is nearly always Group 2: water, milk, juice, wort, glycol and steam are all Group 2. Steam counts as a gas. Multiply PS by V and read the category from the appropriate table in Annex II of the directive. The chamber with the highest category sets the category of the unit.

A small sanitary shell-and-tube unit with 6 bar plant water on one side and 3 bar product on the other, with a few liters per side, usually falls under sound engineering practice or category I. Put 10 bar steam in a large shell and the same unit lands in category II or III.

  • Classify each side separately and take the highest
  • Steam and vapor are gases for the table, which raises the category
  • Fluid group is about the hazard of the fluid, not its cleanliness

Pressure times volume, side by side, puts the unit in its category.

  • Milk, water, steam and glycol are all Group 2
  • Category I self-assessed under module A, no notified body
  • PED hydrotest 1.43 times PS against ASME 1.3

Sound engineering practice and category I

Equipment below the category I threshold is designed and built to sound engineering practice: it must be safe, the maker keeps records, but no CE mark is applied and no notified body is involved. Category I is self-assessed under module A: the maker designs to the essential safety requirements, keeps a technical file, issues a declaration of conformity and applies the CE mark, again with no notified body. Many sanitary exchangers on water and low-pressure product fall here.


Categories II to IV and the notified body

From category II upward a notified body, an organization accredited by an EU member state, takes part. The modules describe how: monitoring the maker's quality system, examining the design, or inspecting the finished unit. For a one-off sanitary exchanger in category II or III the common route is a design examination of the drawings and calculations plus inspection and witnessed testing of the unit, after which the notified body's four-digit number goes on the nameplate beside the CE mark. Category IV applies to large steam vessels and is unusual on sanitary duty. The notified body also checks that materials comply, which for stainless means either an EN material grade with an EN 10204 3.1 certificate or a particular material appraisal for an ASTM grade.


PED and ASME on the same unit

A sanitary exchanger that ships to a European plant from a North American shop is commonly designed to ASME Section VIII and assessed under PED with ASME as the design code. The unit may carry both the U-stamp and the CE mark. The main points of friction are materials, where ASTM stainless grades need a particular material appraisal or a dual-certified EN equivalent; the hydrotest pressure, where PED uses 1.43 times PS against ASME's 1.3; and the technical file, which PED requires to be retained by the maker for ten years.


Specifying PED

Give the destination, the PS and TS each side, the fluids, and whether an ASME stamp is also required. The fabricator classifies the unit, names the module and the notified body if one is needed, and quotes the assessment as a line item.
Call and talk it through with an engineer: 1-805-484-2992

Questions for a European Order

Not to that chamber, if its maximum allowable pressure PS is 0.5 bar gauge or less, which is the lower limit of the directive. The product side of a gravity-fed cooler can sit outside PED while the steam side of the same shell is category II. The trap is in what PS means: it is the most the chamber may ever see, so a CIP pump that can deadhead against a closed valve at 4 bar sets PS at 4 bar, not the 0.3 bar the product runs at. The good news is that a 4 bar liquid chamber on a Group 2 fluid stays in sound engineering practice at any volume a sanitary exchanger will have, because Group 2 liquids do not reach category I until PS exceeds 10 bar. Declare the real PS and let the classification follow.

The EU declaration of conformity and the instructions for use in a language accepted in the country of installation; everything else is a separate deliverable. The technical file, with the calculations, material certificates and test records, stays with the maker for ten years and is produced for the authorities on request, so plant QA does not receive it by default. If the plant wants drawings, 3.1 certificates and the hydrotest report in hand, list them on the order and they ship with the unit.

The skid may become a PED assembly, assessed as a whole in addition to the exchanger's own CE mark. Whoever builds the skid and places it on the market owns that assessment, including the safety accessories: the relief valve that protects the exchanger from the CIP pump deadhead, and the pressure limiter on the steam side. A CE-marked exchanger does not make the skid CE marked. The common failure is discovering at installation that nobody carried the assembly file, so agree before order whether the skid builder or we take it. Give the relief set pressures and the steam regulator setting with the inquiry; they fix PS for each chamber.

When a fluid on either side is classed as flammable, toxic, oxidizing or explosive; on sanitary duty that is almost always high-proof ethanol or an extraction solvent. The stricter tables move the unit a category up at the same PS and V. For a distillery condenser the ethanol vapor counts as a gas, so a chamber at 300 bar liters is category III in Group 1 where water vapor at the same PS times V would be category II. That is the difference between a design examination with a notified body and a self-declared file. Name the fluid and its concentration on the inquiry; a 40 percent ethanol liquid is treated differently from 95 percent vapor.

Related

ASME U-Stamp, National Board and CRN

Design & Fabrication

ASME & CRN

The pressure-code path for a sanitary exchanger in the US and Canada, from design review to the nameplate.

+ Learn More
TEMA Classes and the 3-A Symbol

Design & Fabrication

TEMA & 3-A Marks

A mechanical design standard and a verified sanitary mark: what each adds to the drawing and to the plate.

+ Learn More
Codes and Certification for Sanitary Heat Exchangers

Design & Fabrication

Codes & Certification

Pressure codes, registration numbers and sanitary marks: what each is, who requires it, and where it goes.

+ Learn More