TEMA, the Tubular Exchanger Manufacturers Association, publishes the standards most shell-and-tube exchangers in North America are designed to. It defines the three-letter type designation (a BEM, an AEU, a BEW), the mechanical tolerances, baffle and tie-rod rules, tube hole tolerances, corrosion allowances and the minimum thicknesses, in three classes of increasing severity: C, B and R. It is not a pressure code and there is no TEMA stamp; it is the fabricator's design basis, named on the drawing.

The 3-A symbol is different in kind. It is a registered mark applied to equipment built in conformance with a specific 3-A Sanitary Standard by a fabricator holding a current authorization, verified by a third party. It appears on the nameplate with an authorization number, and it is what a dairy or food inspector reads. It says nothing about pressure or mechanical design.

TEMA Class

  • Design basis named on the drawing
  • Tolerances, baffles, tube holes, minimum thickness
  • No stamp; class C for most sanitary units
VS

3-A Symbol

  • Registered mark on the nameplate
  • Finish, drainability, fittings, elastomers
  • Authorization number checked on the public register

TEMA classes and the 3-A mark

TEMA

  • Class C: Moderate duty, commercial and process; most sanitary and food units
  • Class B: Chemical process service; tighter tolerances and thicker minimums than C
  • Class R: Refinery and severe service; heaviest minimums, largest corrosion allowance
  • Type designation: Front head, shell, rear head letters, e.g. BEM fixed, BEU U-tube
  • Covers: Tolerances, baffles, tie rods, tube holes, minimum thickness, nozzle loads
  • Does not cover: Surface finish, drainability, sanitary fittings, plate or tube-in-tube units

3-A symbol

  • What it is: Registered mark of 3-A Sanitary Standards, Inc.
  • Who applies it: Fabricator holding a current authorization for that standard
  • Basis: Third Party Verification of the design and shop practice
  • On the nameplate: Symbol with the authorization number; standard number optional
  • Verification: Authorization number checked against the 3-A SSI public register
  • Renewal: Periodic re-evaluation; lapsed authorization means no new symbols

TEMA sets the tolerances; 3-A proves the cleanability

Using TEMA and 3-A on a sanitary order

What a TEMA class buys

Specifying TEMA class C on a sanitary shell-and-tube exchanger tells the fabricator to use TEMA's standard tolerances on tube hole diameter and pitch, baffle cut and spacing, shell-to-baffle clearance, and tie rod count; the class C minimum thicknesses and a corrosion allowance appropriate to commercial service; and the standard nomenclature so the drawing reads the same to any engineer. It also brings in TEMA's guidance on flow-induced vibration and on nozzle loads, which matters on long sanitary bundles with thin-wall polished tube.

Class B raises some minimum thicknesses for chemical service but keeps the same 1/16 in carbon steel corrosion allowance as class C; class R goes further for refinery duty with 1/8 in. Neither is needed for a food or pharmaceutical exchanger unless the buyer's corporate standard says so; the extra metal does nothing for cleanability and adds weight and cost. Class C is the sensible default and is what most sanitary units are designed to.

  • Class C: food, dairy, beverage, pharma water, CIP supply
  • Class B: where the buyer's engineering standard requires it across the plant
  • Class R: rarely justified on sanitary duty

Reading a TEMA type

The three letters describe front head, shell and rear head. A BEM is a bonnet front head, single-pass shell and fixed tubesheet rear: the simplest and most common sanitary construction, fully welded on the product side with no internal gaskets. A BEU has the same front head and shell with a U-tube bundle, which absorbs thermal expansion and can be pulled for inspection. An AEW or BEW adds a removable channel and an externally sealed floating tubesheet. For sanitary duty the fixed-tubesheet and U-tube types dominate, because floating-head designs put a gasket inside the shell where it cannot be inspected or cleaned in place.


TEMA class, 3-A symbol and U-stamp are three lines, never one.

  • Class C for food, dairy, beverage and pharma water
  • BEM fixed tubesheet or BEU U-tube for sanitary duty
  • Symbol authorization checked against the public 3-A register

Where TEMA stops on sanitary duty

TEMA is silent on everything that makes an exchanger sanitary. It does not specify surface finish, does not require the unit to drain, does not address sanitary fittings, elastomer compliance or product-side weld grinding, and does not cover plate, tube-in-tube or double-tubesheet arrangements beyond noting that they exist. A specification that reads TEMA class C and nothing more will produce a well-made industrial exchanger with a mill-finish tube side and NPT nozzles. The sanitary requirements have to be added explicitly, and the fabricator applies them on top of the TEMA mechanical design.


The 3-A symbol on the nameplate

The symbol is earned by the fabricator, not by the unit. A shop applies to 3-A SSI for authorization to build to a specific standard (12-08 for tubular exchangers), submits its design, passes a Third Party Verification by a certified evaluator, and recieves an authorization number. Units built to that design may then carry the symbol with that number on the nameplate. The authorization is time-limited and renewed by re-evaluation, and the register of current authorizations is public, so a buyer or inspector can check the number on any plate.

What the symbol tells the inspector is that the product side was designed to the standard and that the shop's practice has been checked. It does not certify the individual unit's finish readings; those are in the finish report. It does not cover pressure; that is the U-stamp beside it. And it does not transfer: a unit modified in the field or rebuilt by a shop without authorization loses the right to the symbol.


Specifying both

Write TEMA class C with the type designation you expect (BEM or BEU for most sanitary units), then the sanitary standard and the symbol requirement as seperate lines, then the pressure code. Three lines, no overlap, no gap.
Call and talk it through with an engineer: 1-805-484-2992

TEMA and Symbol Questions

Usually not; TEMA sets its 1/16 inch class C allowance for carbon steel and leaves alloy parts to be specified by the purchaser. A corrosion allowance assumes metal thins evenly, which is how carbon steel behaves in water. Stainless in CIP service does not thin; it pits or cracks locally at a weld or crevice, and 1/16 inch of extra wall does nothing against a pit. What it does do on a sanitary unit is thicken the tubesheets and heads, add weight and polishing area, and raise price. Where a corporate standard forces an allowance onto stainless, ask for an exception; the right grade buys life, not the extra metal.

Only if the change stays inside the design the conformance evaluator reviewed, or is evaluated again. Length and tube count within the same construction are routine. A relocated product nozzle, an added instrument port or a reshaped head is a new product-contact feature and can take the unit outside the authorization. Raise such changes at drawing review so the evaluation, if one is needed, runs alongside fabrication rather than after a nameplate has been made.

Ask for the authorization certificate before accepting the unit, and check the register when the drawing is submitted rather than at delivery. A number can be absent for innocent reasons, such as a renewal in progress or a listing under a parent company name. But a symbol applied under a lapsed or wrong authorization is treated by a dairy inspector as no symbol at all, and the plant, not the fabricator, carries the citation. Our authorization number goes on the quote so you can look it up before you order.

Yes, wherever steam or fast water crosses a long unsupported span of thin-wall tube on the shell side. Sanitary bundles use 0.065 inch wall polished tube, lighter than most industrial tube, and a span that would be stiff in heavier wall can be driven into vortex shedding or fluid-elastic instability by shell-side velocity. The wear shows at the baffle holes and, worse, as a cracked tube joint at the product-side tubesheet, which on a single-tubesheet unit is the only seal between the fluids. The fix is baffle spacing set from the check, often closer than pressure drop alone would choose. Ask for the TEMA vibration analysis to be run and recorded whenever shell-side flow is high; it costs little at design and nothing after.

No. They are designed to the pressure code directly, with the builder's own tolerances doing the job TEMA does for shell-and-tube. On such orders the pressure code, the sanitary standard and the drawing carry the specification, so the drawing has to fix what the installer needs: connection centerlines, overall length, the plate-pack dimension on a plate unit, and support points. Writing TEMA class C onto a plate exchanger order adds nothing and raises a question that stalls the quote while someone asks what was meant.

Related

ASME U-Stamp, National Board and CRN

Design & Fabrication

ASME & CRN

The pressure-code path for a sanitary exchanger in the US and Canada, from design review to the nameplate.

+ Learn More
PED and CE Marking

Design & Fabrication

PED

How a sanitary exchanger is classified, assessed and CE marked under the Pressure Equipment Directive.

+ Learn More
Codes and Certification for Sanitary Heat Exchangers

Design & Fabrication

Codes & Certification

Pressure codes, registration numbers and sanitary marks: what each is, who requires it, and where it goes.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Engineering - Sales