TEMA Classes and the 3-A Symbol

A mechanical design standard and a verified sanitary mark: what each adds to the drawing and to the plate.

Contact us

Two marks that get confused with codes

TEMA, the Tubular Exchanger Manufacturers Association, publishes the standards most shell-and-tube exchangers in North America are designed to. It defines the three-letter type designation (a BEM, an AEU, a BEW), the mechanical tolerances, baffle and tie-rod rules, tube hole tolerances, corrosion allowances and the minimum thicknesses, in three classes of increasing severity: C, B and R. It is not a pressure code and there is no TEMA stamp; it is the fabricator's design basis, named on the drawing.

The 3-A symbol is different in kind. It is a registered mark applied to equipment built in conformance with a specific 3-A Sanitary Standard by a fabricator holding a current authorization, verified by a third party. It appears on the nameplate with an authorization number, and it is what a dairy or food inspector reads. It says nothing about pressure or mechanical design.

TEMA Class

  • Design basis named on the drawing
  • Tolerances, baffles, tube holes, minimum thickness
  • No stamp; class C for most sanitary units
VS

3-A Symbol

  • Registered mark on the nameplate
  • Finish, drainability, fittings, elastomers
  • Authorization number checked on the public register

TEMA classes and the 3-A mark

TEMA

  • Class C: Moderate duty, commercial and process; most sanitary and food units
  • Class B: Chemical process service; tighter tolerances and thicker minimums than C
  • Class R: Refinery and severe service; heaviest minimums, largest corrosion allowance
  • Type designation: Front head, shell, rear head letters, e.g. BEM fixed, BEU U-tube
  • Covers: Tolerances, baffles, tie rods, tube holes, minimum thickness, nozzle loads
  • Does not cover: Surface finish, drainability, sanitary fittings, plate or tube-in-tube units

3-A symbol

  • What it is: Registered mark of 3-A Sanitary Standards, Inc.
  • Who applies it: Fabricator holding a current authorization for that standard
  • Basis: Third Party Verification of the design and shop practice
  • On the nameplate: Symbol with the authorization number; standard number optional
  • Verification: Authorization number checked against the 3-A SSI public register
  • Renewal: Periodic re-evaluation; lapsed authorization means no new symbols

TEMA sets the tolerances; 3-A proves the cleanability

Using TEMA and 3-A on a sanitary order

What a TEMA class buys

Specifying TEMA class C on a sanitary shell-and-tube exchanger tells the fabricator to use TEMA's standard tolerances on tube hole diameter and pitch, baffle cut and spacing, shell-to-baffle clearance, and tie rod count; the class C minimum thicknesses and a corrosion allowance appropriate to commercial service; and the standard nomenclature so the drawing reads the same to any engineer. It also brings in TEMA's guidance on flow-induced vibration and on nozzle loads, which matters on long sanitary bundles with thin-wall polished tube.

Class B raises the minimums and tightens the corrosion allowance for chemical service, and class R goes further for refinery duty. Neither is needed for a food or pharmaceutical exchanger unless the buyer's corporate standard says so; the extra metal does nothing for cleanability and adds weight and cost. Class C is the sensible default and is what most sanitary units are designed to.

  • Class C: food, dairy, beverage, pharma water, CIP supply
  • Class B: where the buyer's engineering standard requires it across the plant
  • Class R: rarely justified on sanitary duty

Reading a TEMA type

The three letters describe front head, shell and rear head. A BEM is a bonnet front head, single-pass shell and fixed tubesheet rear: the simplest and most common sanitary construction, fully welded on the product side with no internal gaskets. A BEU has the same front head and shell with a U-tube bundle, which absorbs thermal expansion and can be pulled for inspection. An AEW or BEW adds a removable channel and an externally sealed floating tubesheet. For sanitary duty the fixed-tubesheet and U-tube types dominate, because floating-head designs put a gasket inside the shell where it cannot be inspected or cleaned in place.


Where TEMA stops on sanitary duty

TEMA is silent on everything that makes an exchanger sanitary. It does not specify surface finish, does not require the unit to drain, does not address sanitary fittings, elastomer compliance or product-side weld grinding, and does not cover plate, tube-in-tube or double-tubesheet arrangements beyond noting that they exist. A specification that reads TEMA class C and nothing more will produce a well-made industrial exchanger with a mill-finish tube side and NPT nozzles. The sanitary requirements have to be added explicitly, and the fabricator applies them on top of the TEMA mechanical design.


The 3-A symbol on the nameplate

The symbol is earned by the fabricator, not by the unit. A shop applies to 3-A SSI for authorization to build to a specific standard (12-07 for tubular exchangers), submits its design, passes a Third Party Verification by a certified evaluator, and receives an authorization number. Units built to that design may then carry the symbol with that number on the nameplate. The authorization is time-limited and renewed by re-evaluation, and the register of current authorizations is public, so a buyer or inspector can check the number on any plate.

What the symbol tells the inspector is that the product side was designed to the standard and that the shop's practice has been checked. It does not certify the individual unit's finish readings; those are in the finish report. It does not cover pressure; that is the U-stamp beside it. And it does not transfer: a unit modified in the field or rebuilt by a shop without authorization loses the right to the symbol.


Specifying both

Write TEMA class C with the type designation you expect (BEM or BEU for most sanitary units), then the sanitary standard and the symbol requirement as separate lines, then the pressure code. Three lines, no overlap, no gap. Call and talk it through with an engineer: 1-805-484-2992

Common FAQs

No. It is an industry standard adopted by specification. ASME is the legal requirement for pressure; TEMA governs the mechanical design details the code leaves to the fabricator.

No. TEMA covers shell-and-tube exchangers only. Plate units are designed to the pressure code and the plate maker's standards, and their sanitary conformance is under 3-A 11-09.

It covers product-contact surfaces and the non-product surfaces that affect cleanability, such as the exterior finish and the supports. It does not address the pressure design of the shell or the utility side.

Compliant is a claim that the design follows the standard. Authorized means a third party verified it and the fabricator may apply the symbol. Only the second puts a symbol on the plate.

Related

ASME U-Stamp, National Board and CRN

Design & Fabrication

ASME & CRN

The pressure-code path for a sanitary exchanger in the US and Canada, from design review to the nameplate.

+ Learn More
PED and CE Marking

Design & Fabrication

PED

How a sanitary exchanger is classified, assessed and CE marked under the Pressure Equipment Directive.

+ Learn More
Codes and Certification for Sanitary Heat Exchangers

Design & Fabrication

Codes & Certification

Pressure codes, registration numbers and sanitary marks: what each is, who requires it, and where it goes.

+ Learn More

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Engineering - Sales